Related Experiment Video
Updated: Jun 12, 2026

Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Reliability of anion gap calculated from data obtained using a blood gas analyzer: is the probability of error
Norio Otani1, Sachiko Ohde, Toshiaki Mochizuki
1Department of Emergency and Critical Care Medicine, St. Luke's International Hospital, Tokyo 104-8560, Japan. oono@luke.or.jp
Background:
Anion gap (AG) is a useful index for assessing the clinical condition of critically ill patients especially in intoxication. Recently, AG can be obtained easily using a blood gas analyzer (BGA); however, its reliability requires validation.
Methods:
We enrolled patients who simultaneously underwent blood gas analysis and blood test in the central hospital laboratory and patients who visited the emergency department of our hospital from January 1, 2004, to December 31, 2007. The deviation of AG calculated using the BGA and that calculated by the central hospital laboratory were extracted. From the data obtained using the BGA, the independent risk factor causing a significant error in AG was statistically analyzed.
Results:
A total of 2922 patients were enrolled, of which 339 were defined as the significant error group. Male sex, abnormal Hco(3)(-), abnormal lactate, abnormal K, abnormal Cl, and abnormal Na were the independent risk factors producing the significant error. The results indicate that regardless of whether the original electrolyte data of the patients are abnormal, when the electrolyte measurement results obtained using the BGA are abnormal, the calculated AG might show a significant error. In addition, the fact that lactate was determined as a risk factor indicates that AG might be more useful in patients who have intoxication than in those under an unstable state in terms of vital signs.
Conclusion:
When risk factors are present, the medical condition of a patient should be reevaluated by comparing results without heavily relying on the AG obtained by a BGA.
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Errors occurring during blood pressure monitoring
Several factors...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5% chance...