Related Experiment Video
Updated: Jun 11, 2026

Surface-enhanced Resonance Raman Scattering Nanoprobe Ratiometry for Detecting Microscopic Ovarian Cancer via Folate Receptor Targeting
Published on: March 25, 2019
Raman spectroscopy: a novel experimental approach to evaluating renal tumours
Karim Bensalah1, Julien Fleureau, Denis Rolland
1Inserm, U 642, Rennes, F-35000, France. karim.bensalah@chu-rennes.fr
Background:
New optical techniques of spectroscopy have shown promising results in the evaluation of solid tumours.
Objective:
To evaluate the potential of Raman spectroscopy (RS) to assess renal tumours at surgery.
Design, Setting, And Participants:
Over a 5-mo period, Raman optical spectra were prospectively acquired on surgical renal specimens removed due to suspicion of cancer.
Measurements:
Raman measures were normalised to ensure comparison between spectra. A lower resolution signal was computed using a wavelet decomposition procedure to diminish the size of the signal and exploit the complete spectrum. A support vector machine (SVM) with a linear kernel and a sequential minimal optimisation solver was applied. A leave-one-out cross-validation technique was used to train and test the SVM.
Results And Limitations:
There were 36 patients with 34 malignant tumours (27 clear-cell, 6 papillary, and 1 chromophobe) and 2 benign (1 oncocytoma and 1 metanephric cyst) tumours. A total of 241 analysable Raman spectra were obtained. The SVM was able to classify tumoural and normal tissue with an accuracy of 84% (sensitivity 82%, specificity 87%). High-grade and low-grade tumours were differentiated with a precision of 82% (sensitivity 84%, specificity 80%). Histologic subtype could be categorised with an accuracy of 93% (sensitivity 96%, specificity 87%). SVM could not be applied to classify benign and malignant tumours because of the restricted number of benign spectra.
Conclusions:
RS can accurately differentiate normal and tumoural renal tissue, low-grade and high-grade renal tumours, and histologic subtype of renal cell carcinoma. Larger prospective studies are needed to confirm these preliminary data.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
