Related Experiment Video
Updated: Jun 11, 2026

Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Steam sterilization validation for implementation of parametric release at a healthcare facility
Donna Swenson1, Jonathan A Wilder, Charles O Hancock
1West Suburban Medical Center, Oak Park, IL, USA. donna.swenson@att.net
Abstract:
Hospitals are under continual pressure to improve turnaround times for surgical procedures and to find ways to release sterilized product without the need to wait for biological indicator (BI) results. Current procedures used in healthcare do not allow for release of sterilized products based on parameters because hospitals do not validate their sterilization processes. Once a sterilization process is validated for a particular product family, those loads may be released based upon evaluation of the sterilization parameters achieved in the cycle, i.e., parametric release. Typically, hospitals do not perform validation studies to demonstrate that a sterility assurance level (SAL) of 10(-6) is being achieved in the sterilized product, relying instead on inactivation of BIs and/or chemical indicators (CIs) in each load. If a healthcare facility can demonstrate achievement ofa SAL of l0(-6) in a particular product family then it will be possible to release the products in that product family based on achievement of parameters without waiting for BI results. This does not mean that the healthcare facility can eliminate use of all BIs and CIs as part of the criteria for a comprehensive quality assurance program, but dependence on their results and the cost of their use may be greatly reduced. Validation provides another component in a quality assurance program to demonstrate that the highest SAL possible is being provided to patients while still providing the services required by today's healthcare facility.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Scale-Up Processes