Related Experiment Video
Updated: Jun 11, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Multi-pass Shack-Hartmann planeness test: monitoring thermal stress
1Institute for Optics, Information and Photonics, and Max Planck Institute for the Science of Light Friedrich Alexander University of Erlangen-Nürnberg Staudtstr. 7/B2, 91058 Erlangen, Germany. johannes.schwider@physik.uni-erlangen.de
Abstract:
The multi-pass solution for surface measurements with the help of a Shack-Hartmann sensor (SHS) on the basis of a Fizeau cavity enables fast access to surface deviation data due to the high speed of the SHS and easy referencing of the measured data through difference measurements. The multi-pass solution described in a previous publication [J. Schwider, Opt. Express 16, 362 (2008)], provides highly sensitive measurements of small displacements caused by thermal non-equilibrium states of the test set up. Here, we want to demonstrate how a pulsed thermal load changes the surface geometry. In addition the temporal response for different plate materials is monitored through a fast wave front measurement with very high sensitivity. The thermal load close to a delta-function in time will be applied from the back-side of a plane plate by heating a small Peltier element with a heat impulse of known order of magnitude. The development of the surface deviation on the time axis can be monitored by storing a set of successive deviation pictures.
Related Concept Videos
Thermal Stress
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...

