Optical pulse coding in hybrid distributed sensing based on Raman and Brillouin scattering employing Fabry-Perot
Gabriele Bolognini1, Marcelo A Soto
1Scuola Superiore Sant'Anna, via G. Moruzzi 1, 56124 Pisa, Italy. gabriele.bolognini@sssup.it
Abstract:
We demonstrate simultaneous strain and temperature sensing based on hybrid Raman and Brillouin scattering with enhanced performance thanks to the combined use of standard Fabry-Perot lasers in conjunction with optical pulse coding techniques. The combination of both techniques allows for an improvement of ~8.7 dB in temperature resolution and ~3 dB in strain resolution, with respect to standard distributed feedback lasers, as confirmed by experiments, resulting in a final temperature / strain resolution of ~0.27K / ~30microepsilon over 25-km sensing fiber range, avoiding the use of optical amplification and wavelength averaging techniques.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...