Related Experiment Video
Updated: Jun 11, 2026

Capillary Electrophoresis to Monitor Peptide Grafting onto Chitosan Films in Real Time
Published on: October 26, 2016
Spermine-graft-dextran non-covalent copolymer as coating material in separation of basic proteins and
Ai-Jun Wang1, Jiu-Ju Feng, Wen-Ju Dong
1School of Chemistry and Environmental Science, Henan Key Laboratory for Environmental Pollution Control, Key Laboratory for Yellow and Huai Rivers Water Environment and Pollution Control, Key Laboratory of green chemical media and reactions, Henan Normal University, Xinxiang, Henan 453007, China. ajwangnju@gmail.com
Abstract:
Spermine-graft-dextran (Spe-g-Dex) copolymer was synthesized and used as a non-covalent coating for the separation of proteins and neurotransmitters by capillary electrophoresis. The coating was obtained via flushing the capillary with 1.0% Spe-g-Dex copolymer solution for 2min. Electroosmotic flow (EOF) was strongly suppressed, ranging from -1.60x10(-9) to 3.65x10(-9)m(2)V(-1)s(-1). Effect of experimental conditions, such as the copolymer concentration, the concentration and pH of the background electrolyte (BGE), on the Spe-g-Dex coating was investigated. Separation of lysozyme, cytochrome c, ribonuclease A and alpha-chymotrypsinogen yielded high separation efficiencies ranging from 141000 to 303000plates/m and recoveries from 85.4% to 98.3% at pH 4.0 (284.0mM sodium acetate-acetic acid buffer, I=50mM). Run-to-run repeatabilities and day-to-day, and capillary-to-capillary reproducibilities were all below 1.7%. In addition, Spe-g-Dex coating allowed the successful separation of five neurotransmitters, 5-hydroxytryptamine, dopamine, epinephrine, isoprenaline, dobuamine at pH 4.0 with high separation efficiencies of 290000-449000plates/m.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...