Increased duration of mechanical ventilation is associated with decreased diaphragmatic force: a prospective
Greet Hermans1, Anouk Agten, Dries Testelmans
1Medical Intensive Care Unit, General Internal Medicine, University Hospitals Leuven, Herestraat 49, B3000 Leuven, Belgium. Greet.Hermans@uz.kuleuven.be
Introduction:
Respiratory muscle weakness is an important risk factor for delayed weaning. Animal data show that mechanical ventilation itself can cause atrophy and weakness of the diaphragm, called ventilator-induced diaphragmatic dysfunction (VIDD). Transdiaphragmatic pressure after magnetic stimulation (TwPdi BAMPS) allows evaluation of diaphragm strength. We aimed to evaluate the repeatability of TwPdi BAMPS in critically ill, mechanically ventilated patients and to describe the relation between TwPdi and the duration of mechanical ventilation.
Methods:
This was a prospective observational study in critically ill and mechanically ventilated patients, admitted to the medical intensive care unit of a university hospital. Nineteen measurements were made in a total of 10 patients at various intervals after starting mechanical ventilation. In seven patients, measurements were made on two or more occasions, with a minimum interval of 24 hours.
Results:
The TwPdi was 11.5 ± 3.9 cm H2O (mean ± SD), indicating severe respiratory muscle weakness. The between-occasion coefficient of variation of TwPdi was 9.7%, comparable with data from healthy volunteers. Increasing duration of mechanical ventilation was associated with a logarithmic decline in TwPdi (R = 0.69; P = 0.038). This association was also found for cumulative time on pressure control (R = 0.71; P = 0.03) and pressure-support ventilation (P = 0.05; R = 0.66) separately, as well as for cumulative dose of propofol (R = 0.66; P = 0.05) and piritramide (R = 0.79; P = 0.01).
Conclusions:
Duration of mechanical ventilation is associated with a logarithmic decline in diaphragmatic force, which is compatible with the concept of VIDD. The observed decline may also be due to other potentially contributing factors such as sedatives/analgesics, sepsis, or others.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Atelectasis II: Pathophysiology