Reliability of intrabladder pressure measurement in intensive care
Melanie Horbal Shuster1, Tammy Haines, L Kathleen Sekula
1West Penn Allegheny Health System, Allegheny Center for Digestive Health, Pittsburgh, Pennsylvania, USA. mshuste1@wpahs.org
Background:
The reliability of intrabladder pressure measurements obtained in nonsupine patients is unknown.
Objectives:
To investigate the reliability of measurements of intrabladder pressure obtained with 30 degrees head-of-bed elevation.
Methods:
With patients supine, 30 degrees head-of-bed elevation, and instillation of 0 and 25 mL physiological saline, intrabladder pressure was measured in 10 patients: twice by one nurse to assess intraobserver reliability and once by a different nurse to assess interobserver reliability. Data were analyzed by using paired t tests, Pearson correlation, and Bland-Altman analysis.
Results:
For intraobserver reliability, measurements obtained with no instillation (mean difference, -1.8; 95% confidence interval [CI], -4.9 to 1.3; P = .22) and with instillation of 25 mL (mean difference, -0.6; 95% CI, -1.8 to 0.6; P = .28) did not differ significantly. Pearson r values were 0.74 and 0.81, respectively. Estimated Bland-Altman bias and limits of agreements were -1.8 and -10.3 to 6.7 mm Hg and -0.6 and -3.82 to 2.62 mm Hg, respectively. For interobserver reliability, measurements obtained with no instillation (mean difference, 1.0; 95% CI, -2.2 to 4.2; P = .49) and with instillation of 25 mL (mean difference, -0.7; 95% CI, -2.45 to 1.05; P = .39) did not differ significantly. Pearson r values were 0.78 and 0.82, respectively. Estimated Bland-Altman bias and limits of agreement were 1.0 and -7.76 to 9.76 mm Hg and -0.7 and -5.5 to 4.0 mm Hg, respectively.
Conclusions:
Reliability of intrabladder pressure measurements obtained with 30 degrees head-of-bed elevation is strong.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...