Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Genetic Evolutionary Analysis and Characterization of Bovine Viral Diarrhea Virus in Gansu Province, China.

Viruses·2026
Same author

Identification and Genome Phylogenetic Analysis of Three <i>Brucella abortus</i> Strains From Sheep, Yak, and Cow in Qinghai, China.

Transboundary and emerging diseases·2026
Same author

Scalable Fabrication of Cataluminescent Sensing Films with Enhanced Selectivity for <i>Iso</i>-Butanol over Structural Isomers.

Analytical chemistry·2025
Same author

Identification and phylogenetic analysis of a Brucella canis Isolate from an aborted canine fetus.

Veterinary microbiology·2025
Same author

Dual-functional platform based on 315-nm Stokes shift Al, N-doped carbon dots for Hg<sup>2+</sup> onsite detection and removal.

Mikrochimica acta·2025
Same author

The combinatorial activities of oseltamivir and molnupiravir against influenza virus infections in vitro and in vivo.

Virology·2025

Related Experiment Video

Updated: Jun 11, 2026

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
08:12

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

Published on: March 13, 2013

A highly sensitive and selective dimethyl ether sensor based on cataluminescence.

Runkun Zhang1, Xiaoan Cao, Yonghui Liu

  • 1Environmental Science and Engineering Institute, Guangzhou University, Guangzhou, China.

Talanta
|July 7, 2010
PubMed
Summary

A new sensor detects dimethyl ether (DME) using cataluminescence on a ceramic heater. This highly sensitive and selective sensor offers a low detection limit and fast response, ideal for air quality monitoring.

More Related Videos

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
08:22

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor

Published on: February 16, 2018

Fabrication of polydimethylsiloxane (PDMS)-Based Flexible Surface-Enhanced Raman Scattering (SERS) Substrate for Ultrasensitive Detection
03:33

Fabrication of polydimethylsiloxane (PDMS)-Based Flexible Surface-Enhanced Raman Scattering (SERS) Substrate for Ultrasensitive Detection

Published on: November 17, 2023

Related Experiment Videos

Last Updated: Jun 11, 2026

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
08:12

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

Published on: March 13, 2013

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
08:22

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor

Published on: February 16, 2018

Fabrication of polydimethylsiloxane (PDMS)-Based Flexible Surface-Enhanced Raman Scattering (SERS) Substrate for Ultrasensitive Detection
03:33

Fabrication of polydimethylsiloxane (PDMS)-Based Flexible Surface-Enhanced Raman Scattering (SERS) Substrate for Ultrasensitive Detection

Published on: November 17, 2023

Area of Science:

  • Chemical Sensors
  • Materials Science
  • Environmental Monitoring

Background:

  • Dimethyl ether (DME) is a volatile organic compound with various industrial applications.
  • Accurate and sensitive detection of DME in ambient air is crucial for safety and environmental assessment.
  • Existing detection methods may require complex procedures or lack sufficient sensitivity and selectivity.

Purpose of the Study:

  • To design and develop a novel sensor for dimethyl ether detection.
  • To investigate the sensor's performance characteristics, including sensitivity, selectivity, and detection limit.
  • To explore the underlying cataluminescence mechanism for DME oxidation on a ceramic heater surface.

Main Methods:

  • Utilized the cataluminescence phenomenon occurring on a ceramic heater surface upon exposure to DME vapors.
  • Optimized operating temperature, detection wavelength (425 nm), and carrier air flow rate (300 mL/min).
  • Performed quantitative analysis to determine the linear range and detection limit of the sensor.

Main Results:

  • The sensor demonstrated high sensitivity and selectivity towards dimethyl ether at an optimal temperature of 279°C.
  • Achieved a linear detection range of 100–6.0x10³ ppm with a low detection limit of 80 ppm.
  • Exhibited a rapid response time of 2.5 seconds and minimal interference from common volatile organic compounds.

Conclusions:

  • The developed cataluminescence-based sensor offers a simple, cost-effective, and stable method for dimethyl ether detection.
  • The sensor's performance characteristics make it suitable for practical applications in air quality monitoring.
  • The study provides insights into the cataluminescence mechanism of DME oxidation, paving the way for further sensor development.