Management of malignant air leak in a child with a neonatal high-frequency oscillatory ventilator
T C Mayes1, L S Jefferson, Y David
1Department of Pediatrics, Baylor College of Medicine, Houston, Texas.
Abstract:
A 10-year-old, 36-kg child with a malignant air leak who failed conventional mechanical ventilation and high-frequency jet ventilation was successfully treated with a neonatal high-frequency oscillatory ventilator for 31 days. Since the air leak resolved with minimal hemodynamic compromise, this technique may have application in the management of respiratory failure and air leak in the older and larger child for prolonged periods of time.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Cardiopulmonary Resuscitation II: ACLS Airway Management