Related Experiment Video

Updated: Jun 11, 2026

Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
08:04

Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis

Published on: March 11, 2017

Effect of fracture gap on stability of compression plate fixation: a finite element study

Gary S Beaupre

    Journal of Orthopaedic Research : Official Publication of the Orthopaedic Research Society
    |July 8, 2010
    PubMed
    Abstract

    No abstract available in PubMed .

    More Related Videos

    Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
    06:59

    Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents

    Published on: August 14, 2018

    Related Experiment Videos

    Last Updated: Jun 11, 2026

    Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
    08:04

    Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis

    Published on: March 11, 2017

    Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
    06:59

    Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents

    Published on: August 14, 2018

    Related Concept Videos

    Behavior of Concrete Under Compressive Load01:23

    Behavior of Concrete Under Compressive Load

    Concrete exhibits specific behaviors under different compressive loads. Understanding this is crucial for understanding its structural integrity. When concrete undergoes uniaxial compression, it tends to develop cracks that run parallel to the direction of the force. These parallel cracks stem from localized tensile stresses that occur perpendicular to the compression direction. Additionally, angled cracks may appear due to the formation of shear planes.
    As the concrete specimen fractures under...
    Temperature Dependent Deformation01:12

    Temperature Dependent Deformation

    In a nonhomogeneous rod made up of steel and brass, restrained at both ends and subjected to a temperature change, several steps are involved in calculating the stress and compressive load. Due to the problem's static indeterminacy, one end support is disconnected, allowing the rod to experience the temperature change freely. Next, an unknown force is applied at the free end, triggering deformations in the rod's steel and brass portions. These deformations are then calculated and added together...

    Articles linked to this work by shared authors, journal, and citation graph.

    Personalised gait retraining for medial compartment knee osteoarthritis: a randomised controlled trial.

    The Lancet. Rheumatology·2025

    Personalization improves the biomechanical efficacy of foot progression angle modifications in individuals with medial knee osteoarthritis.

    Journal of biomechanics·2022

    Corrigendum: Long-Term Cognitive Impairments and Pathological Alterations in a Mouse Model of Repetitive Mild Traumatic Brain Injury.

    Frontiers in neurology·2022

    Changes in foot progression angle during gait reduce the knee adduction moment and do not increase hip moments in individuals with knee osteoarthritis.

    Journal of biomechanics·2022

    Tibiofemoral forces during FES rowing in individuals with spinal cord injury.

    Computer methods in biomechanics and biomedical engineering·2020

    Rapid volumetric gagCEST imaging of knee articular cartilage at 3 T: evaluation of improved dynamic range and an osteoarthritic population.

    NMR in biomedicine·2020

    The Human ACL Sheath Exhibits Distinct Transcriptomic Signatures and Functional Properties.

    Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2026

    SPOT: An Early Detection Tool for Predicting Pain Trajectories Following Intra-Articular Injections.

    Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2026

    Addressing Overlooked Variables in Preclinical Fracture Repair Research for Improved Translation.

    Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2026

    Lanthionine Ketenamine Derivative Enhances Early Functional Recovery Following Skeletal Muscle Ischemia-Reperfusion Injury Through Modulation of Autophagy and Oxidative Stress.

    Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2026

    A Novel Preclinical Rat Model of Acute Compartment Syndrome.

    Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2026

    Comparative Wear Behavior of Titanium Nitride-Coated Titanium and Cobalt Chromium Femoral Components in Cementless Total Knee Arthroplasty.

    Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2026

    Development of a multi-technique analytical strategy for the thermal stability assessment of recombinant humanized type III collagen.

    Analytical methods : advancing methods and applications·2026

    Preoperative Frailty Correlates With Progression of Lateral Compartment Osteoarthritis After Medial Unicompartmental Knee Arthroplasty: A Mean 70-month Follow-up Study.

    The Journal of the American Academy of Orthopaedic Surgeons·2026

    Atomistic framework for glassy polymer viscoelasticity across twenty frequency decades.

    The Journal of chemical physics·2026

    Helical Blade Versus Lag Screw Fixation in Cephalomedullary Nailing of Unstable Trochanteric Fractures: A Narrative Review.

    Cureus·2026

    Failure Rate After Shoulder Stabilization Procedures in the Military With Use of Knotless Suture Tape: A Case-Control Study.

    Orthopaedic journal of sports medicine·2026

    Minimally Invasive Treatment of Die-Punch Fractures and Related X-Ray Parameters.

    Geriatric orthopaedic surgery & rehabilitation·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us