Related Experiment Video
Updated: Jun 11, 2026

Electrophoretic Separation of Proteins
Published on: June 12, 2008
Ultra-fast two-dimensional microchip electrophoresis using SDS micro-CGE and microemulsion electrokinetic
John K Osiri1, Hamed Shadpour, Steven A Soper
1Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA.
Abstract:
A poly(methyl methacrylate) microfluidic chip was used to perform a two-dimensional (2-D) separation of a complex protein mixture in short development times. The separation was performed by combining sodium dodecyl sulfate micro-capillary gel electrophoresis (SDS micro-CGE) with microemulsion electrokinetic chromatography (micro-MEEKC), which were used for the first and second dimensions, respectively. Fluorescently labeled Escherichia coli cytosolic proteins were profiled by this 2-D approach with the results compared to a similar 2-D separation using SDS micro-CGE x micro-MEKC (micelle electrokinetic chromatography). The relatively short column lengths (effective length = 10 mm) for both dimensions were used to achieve separations requiring only 220 s of development time. High spot production rates (131 +/- 11 spots min(-1)) and reasonable peak capacities (481 +/- 18) were generated despite the fact that short columns were used. In addition, the use of mu-MEEKC in the second dimension was found to produce higher peak capacities compared to micro-MEKC (481 +/- 18 for micro-MEEKC and 332 +/- 17 for micro-MEKC) due to the higher plate numbers associated with micro-MEEKC.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...