Background:
There is some disagreement concerning the minimal value of the interval between components of double potentials (DPs interval) that allows distinguishing complete and incomplete block in the cavotricuspid isthmus (CTI).
Objectives:
To assess clinical utility of the relationship between atrial flutter cycle length (AFL CL) and the DPs interval.
Methods:
Ablation of the CTI was performed in 87 patients during AFL (245 ± 40 ms). Subsequently, DPs were recorded during proximal coronary sinus pacing at sites close to a gap in the ablation line and after achievement of complete isthmus block.
Results:
We noted strong correlation between AFL CL and the DPs interval after achievement of isthmus block (r = 0.73). The mean DPs interval was 95.3 ± 18.3 ms (range 60-136 ms) and 123.3 ± 24.3 ms (range 87-211 ms) during incomplete and complete isthmus block, respectively (P < 0.001). When expressed as a percentage of AFL CL, this interval was 35.7 ± 3.5% AFL CL (range 28-40.2%) and 50.4 ± 6.9% AFL CL (range 39-72%) during incomplete and complete isthmus block, respectively (P < 0.001). A cutoff value of 40% of AFL CL identified CTI block with 96.7% sensitivity and 100% specificity.
Conclusions:
The interval between DPs after achievement of block in the CTI correlates with AFL CL. The DPs interval expressed as a percentage of AFL CL allows better distinguishing between complete and incomplete isthmus block compared to standard method based on milliseconds. The DPs interval below 40% of AFL CL indicates sites close to a gap in the ablation line.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...