Related Experiment Video
Updated: Jun 10, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Low toxic dispersive liquid-liquid microextraction using halosolvents for extraction of polycyclic aromatic
Mei-I Leong1, Chu-Chi Chang, Ming-Ren Fuh
1Department of Chemistry, National Tsing Hua University, Sec. 2, Kung Fu Rd., 101, Hsinchu, Taiwan.
Abstract:
A low toxic dispersive liquid-liquid microextraction (LT-DLLME) combined with gas chromatography-mass spectrometry (GC-MS) had been developed for the extraction and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in water samples. In normal DLLME assay, chlorosolvent had been widely used as extraction solvents; however, these solvents are environmental-unfriendly. In order to solve this problem, we proposed to use low toxic bromosolvent (1-bromo-3-methylbutane, LD(50) 6150mg/kg) as the extraction solvent. In this study we compared the extraction efficiency of five chlorosolvents and thirteen bromo/iodo solvents. The results indicated that some of the bromo/iodo solvents showed better extraction and had much lower toxicity than chlorosolvents. We also found that propionic acid is used as the disperser solvent, as little as 50microL is effective. Under optimum conditions, the range of enrichment factors and extraction recoveries of tap water samples are ranging 372-1308 and 87-105%, respectively. The linear range is wide (0.01-10.00microgL(-1)), and the limits of detection are between 0.0003 and 0.0078microgL(-1) for most of the analytes. The relative standard deviations (RSD) for 0.01microgL(-1) of PAHs in tap water were in the range of 5.1-10.0%. The performance of the method was gauged by analyzing samples of tap water, sea water and lake water samples.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Extraction: Advanced Methods
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...