Related Experiment Video
Updated: Jun 10, 2026

In vitro Investigation of the MexAB Efflux Pump From Pseudomonas aeruginosa
Published on: February 17, 2014
Formation and structure of the potassium complex of valinomycin in solution studied by Raman optical activity
Shigeki Yamamoto1, Michal Straka, Hitoshi Watarai
1Institute of Organic Chemistry and Biochemistry, Academy of Sciences, 166 10 Prague, Czech Republic. aporoa@gmail.com
Abstract:
The formation and structure of the potassium complex with valinomycin in solution were studied by means of Raman and Raman optical activity (ROA) spectroscopy. The complexation caused significant spectral changes, particularly in the region 1200-1400 cm(-1). The experimental spectra were interpreted using first principles computations. A complete computational conformational search combined with the spectral analysis revealed the arrangement of the isopropyl side chains in the complex. From a total of 6579 unique conformers two predominant ones were confirmed in the solution by ROA. A third one was predicted theoretically, but its population in the experiment could be estimated only roughly. The most populated conformer does not exhibit C(3) symmetry, and is different from that present in the crystal and the NMR-derived structure. Molecular dynamics techniques were used to estimate the molecular flexibility and its effect on the spectra. Density functional computations and Cartesian coordinate transfer (CCT) techniques provided the ROA and Raman spectral shapes and intensities well comparable with the experiment. The polar solvent (methanol) environment modeled with a polarizable continuum model (PCM) leads to rather minor changes in the conformer populations and vibrational properties as compared to vacuum computations, due to the hydrophobic character of the complex. Additional computational experiments suggest that the vibrational interactions determining the ROA spectra are quite local, which contributes to the good spatial resolution of the method. A reduction of the noise in the experimental spectra as well as increased precision of the simulations is desirable for the further exploration of the potential of the ROA spectroscopy for biomolecular studies in the future.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Valence Bond Theory
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent of conjugation in the...
Estimation of k and VD of Aminoglycosides
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...