Related Experiment Video
Updated: Jun 10, 2026

Standard Test Method ASTM D 7998-19 for the Cohesive Strength Development of Wood Adhesives
Published on: May 17, 2020
Bracket bond strength comparison between new unfilled experimental self-etching primer adhesive and conventional
Masahiro Iijima1, Shuichi Ito, Takeshi Muguruma
1Department of Oral Growth and Development, Health Sciences University of Hokkaido, Hokkaido, Japan. iijima@hoku-iryo-u.ac.jp
Objective:
To determine if a new unfilled experimental self-etching primer (SEP) adhesive system (SBP-40TX + C&B Metabond) that incorporates a methyl methacrylate-based 4-META/TBB (4-methacryloxyethyl trimellitate anhydride tri-n-butyl borane) resin can provide adequate shear bond strength (SBS) when used for bonding orthodontic brackets.
Methods And Materials:
Forty-eight human maxillary premolars were randomly divided into three groups of 16 specimens each. Brackets were bonded with three bonding systems. A filled Bis-GMA/TEGDM (triethylene glycol dimethacrylate)-based SEP adhesive system (Transbond Plus) and an unfilled conventional etch-and-rinse adhesive system (C&B Metabond) were used for comparison. The SBS for each sample was examined with a universal testing machine, and the Adhesive Remnant Index score was calculated. Enamel surfaces after conditioning were examined using a scanning electron microscope. Data were compared by one-way analysis of variance and a chi(2) test.
Results:
The experimental SEP showed a milder etching pattern than Transbond Plus SEP. No statistically significant differences in the mean SBS were found between the specimens bonded with the unfilled experimental SEP adhesive system (10.0 MPa) and the filled SEP adhesive system (8.7 MPa). The unfilled experimental SEP adhesive system showed less residual adhesive than the filled SEP adhesive system.
Conclusions:
The unfilled experimental SEP adhesive system showed a clinically sufficient SBS that was equivalent to the filled SEP adhesive system.
Related Concept Videos
Bonding and Strength of Aggregate
Accelerators
The effectiveness of calcium chloride can...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...