Related Experiment Video
Updated: Jun 10, 2026

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Molecularly imprinted polymeric microspheres for determination of bovine serum albumin based on flow injection
Jinghua Yu1, Fuwei Wan, Congcong Zhang
1Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, No. 106, Jiwei Road, Jinan 250022, China.
Abstract:
A novel flow injection chemiluminescence (FI-CL) sensor for the determination of bovine serum albumin (BSA) using molecularly imprinted polymeric microspheres (MIPMs) as recognition element is reported. The BSA-MIPM was synthesized by suspension polymerization in toluene, using methacrylic acid (MAA) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker in the bovine serum albumin template molecule. Scanning electron microscope (SEM) was employed to characterize the surface morphology of the resultant imprinted microspheres. Molecular modeling was employed to simulate the possible recognition process of the MIPM. Then the synthesized BSA-MIPM was employed as recognition element by packing into flow cell to establish a novel FI-CL sensor. The chemiluminescence (CL) intensity was correlated linear with the concentration of BSA over the range of 1.0×10(-8) to 5.0×10(-6) g mL(-1) and the detection limit was 1.5×10(-9) g mL(-1). The relative standard deviation (RSD) for the determination of 1.0×10(-7) g mL(-1) BSA was 1.4% (n=11). The sensor is reusable and has a great improvement in sensitivity and selectivity for CL analysis. As a result, the new MIPM-CL sensor had been successfully applied to the determination of BSA in milk samples.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
08:50Multiplexed Fluorescent Microarray for Human Salivary Protein Analysis Using Polymer Microspheres and Fiber-optic Bundles
Published on: October 10, 2013
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.