Related Experiment Video
Updated: Jun 10, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Determination of galanthamine in Bulbus Lycoridis Radiatae by coupling capillary electrophoresis with end-column
Biyang Deng1, Fang Xie, Linqiu Li
1Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), College of Chemistry and Chemical Engineering, Guangxi Normal University, Guilin, P. R. China. dengby16@163.com
Abstract:
A novel method for the determination of galanthamine (GAL) in Bulbus Lycoridis Radiatae has been developed based on coupling CE with an end-column tris(2,2'-bipyridyl)ruthenium(II) electrochemiluminescence (ECL). Parameters affecting CE separation and ECL detection were investigated and optimized. Baseline separation of GAL from other components in the Bulbus Lycoridis Radiatae sample was achieved with an 18 mmol/L phosphate running buffer at pH 9.0. Under the optimized conditions: 12 kV CE-separation voltage, ECL detection potential at 1.25 V with 5 mmol/L Ru(bpy)(3)(2+) and 50 mmol/L phosphate buffer at pH 7.5 in the detection reservoir, the linear range of GAL concentration was from 0.8 ng/mL to 2 microg/mL, whereas the detection limit was 0.25 ng/mL (S/N=3). The proposed method was successfully demonstrated for the determination of GAL in Bulbus Lycoridis Radiatae.