Discrepancies in international normalized ratio results between instruments: a model to split the variation into

Una Ø Sølvik1, Per H Petersen, Grete Monsen

  • 1Department of Public Health and Primary Health Care, Faculty of Medicine and Dentistry, University of Bergen, Norway. una.solvik@isf.uib.no

Clinical Chemistry
|August 6, 2010
PubMed
Summary

Differences in international normalized ratio (INR) measurements between devices are significant. Patient-specific factors contribute to variations, recommending consistent use of a single INR device per patient for reliable monitoring.

Related Concept Videos

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Variability: Analysis01:11

Variability: Analysis

Measures of variability are statistical metrics that reveal the dispersion pattern within a dataset. They are pivotal in biostatistics, providing insights into the heterogeneity within health and biological data. Variability signifies the degree to which data points diverge from one another, helping researchers understand the potential range of values and associated uncertainty within the data.
The range is a simple measure of variability, indicating the difference between the highest and...
Systematic Error: Methodological and Sampling Errors01:15

Systematic Error: Methodological and Sampling Errors

In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...