Related Experiment Video
Updated: Jun 10, 2026

Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Validation of a fast gas chromatographic method for the study of semiochemical slow release formulations
Stéphanie Heuskin1, Eric Rozet, Stéphanie Lorge
1Department of Analytical Chemistry, Gembloux Agro-Bio Tech, Liège University, Passage des Déportés 2, Gembloux, Belgium. stephanie.heuskin@ulg.ac.be
Abstract:
The validation of a fast GC-FID analytical method for the quantitative determination of semiochemical sesquiterpenes (E-beta-farnesene and beta-caryophyllene) to be used in an integrated pest management approach is described. Accuracy profiles using total error as decision criteria for validation were used to verify the overall accuracy of the method results within a well defined range of concentrations and to determine the lowest limit of quantification for each analyte. Furthermore it allowed to select a very simple and reliable regression model for calibration curve for the quantification of both analytes as well as to provide measurement uncertainty without any additional experiments. Finally, this validated method was used for the quantification of semiochemicals in slow release formulations. The goal was to verify the protection efficiency of alginate gel beads formulations against oxidation and degradation of sesquiterpenes. The results showed that the alginate beads are adequate slow release devices which protect the bio-active molecules during at least twenty days.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...

