High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Coupling desorption electrospray ionization with solid-phase microextraction for screening and quantitative analysis
Joseph H Kennedy1, Craig Aurand, Robert Shirey
1Prosolia, Inc., Indianapolis, Indiana, USA.
Abstract:
Direct analysis of silica C(18)-coated solid-phase microextraction (SPME) fibers using desorption electrospray ionization mass spectrometry (DESI-MS) for the purpose of analyzing drugs from raw urine is presented. The method combines a simple, inexpensive, and solvent-less sample preparation technique with the specificity and speed of DESI-MS and MS/MS. Extraction of seven drugs from raw urine is performed using specially designed SPME fibers coated uniformly with silica-C(18) stationary phase. Each SPME device is inserted into unprocessed urine under gentle agitation and, then, removed, rinsed, and analyzed directly by DESI-MS (MS/MS). Rapid screening over a wide mass range is afforded by coupling the method with a time of flight (TOF) mass spectrometer while quantitative analysis is performed using selected reaction monitoring (SRM) using a triple quadrupole mass spectrometer. The performance of the SPME DESI-MS/MS method was evaluated by preparing calibration standards and quality control (QC) samples of the seven drug compounds from urine over a range from 20 to 1000 ng/mL, with the exception of meprobamate which was prepared from 200 to 10000 ng/mL. The calibration curves constructed for each analyte had an R(2) > 0.99. The range of precision (%CV) and accuracy values (% bias) for low QC samples was 1-11% and 3-38%, respectively. Precision and accuracy values for high QC samples range from 0.9 to 8% and -31 to -8%. Results from urine specimens of actual exposure to drugs screened using the SPME DESI-MS/MS method showed good agreement with the conventional immunoassays and GC/MS analysis. Liquid desorption of the SPME fiber followed by LC/MS/MS also showed good agreement with the SPME DESI-MS/MS method.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Electrophoresis: Overview
There...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Types of Detectors