Related Experiment Video
Updated: Jun 10, 2026

Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Method development and validation of capillary sodium dodecyl sulfate gel electrophoresis for the characterization of
Junge Zhang1, Sudhir Burman, Sri Gunturi
1Analytical Development, Johnson and Johnson Pharmaceutical Research and Development, Malvern, PA, USA. jzhang26@its.jnj.com
Abstract:
A capillary sodium dodecyl sulfate gel electrophoresis (cSDS) method has been developed and qualified for purity and impurity analysis of monoclonal antibodies. This method was optimized and qualified for the analysis of monoclonal antibody (mAb1) under reduced and non-reduced conditions. Some of the sample preparation parameters including sample buffer pH, incubation temperature and duration, alkylation conditions with iodoacetamide (IAM), and reduction conditions with 2-mercaptoethanol (2-ME) were optimized. It was observed that under slightly acidic conditions (pH 5.5-6.5) the thermally induced fragmentation of non-reduced mAb1 was greatly decreased. As such, a citrate-phosphate buffer at pH 6.5 was used for sample preparation to replace the original Beckman sample buffer (pH 9.0). The optimal sample preparation conditions were found to be as follows: (1) incubation temperature and duration (reduced and non-reduced), 65 degrees C for 5 min; (2) alkylation condition, 10 microL of 0.25 M IAM; (3) reduction condition, 10 microL of 5-fold diluted 2-ME. The method was qualified by evaluating specificity, accuracy, precision, limit of quantitation (LOQ), and linearity. The method exhibited no interference from sample buffer matrix. The method was found to be linear, accurate, and precise in the range of 0.25-3.0mg/mL protein concentration. The LOQ of the method was determined to be 0.02 mg/mL for reduced and non-reduced mAb1. In addition, some aspects of sample stability were examined during qualification.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
