Related Experiment Video
Updated: Jun 10, 2026

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Spectroscopic measurements of electron densities and gas temperatures in deuterium lamps
Abstract:
Plasma diagnostics results of electron densities and gas temperatures in commercial low-pressure deuterium lamps at current densities from 38 A/cm(-2) to 306 A/cm(-2) are presented. These plasma parameters are obtained by comparing measured and calculated Balmer line profiles, taking into account Stark broadening, Doppler broadening, and the influence of fine structure and the apparatus profile. Results for the plasma spot show a steady increase of electron density from 1.6 x 10(13) cm(-3) to 5.0 x 10(13) cm(-3) and of gas temperature from 1800 to 6800 K.
More Related Videos
06:06A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
Published on: July 19, 2016
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Related Concept Videos
Emission Spectra
UV–Vis Spectrometers
Flame Photometry: Overview
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...