Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with
Yoshiko Sagara1, Amy K Hara, William Pavlicek
1Department of Radiology, Oita University Faculty of Medicine, Idaigaoka Hasama-machi, Yufu-shi, Oita, Japan.
Objective:
The purpose of this article is to retrospectively compare radiation dose, noise, and image quality of abdominal low-dose CT reconstructed with adaptive statistical iterative reconstruction (ASIR) and routine-dose CT reconstructed with filtered back projection (FBP).
Materials And Methods:
Fifty-three patients (37 men and 16 women; mean age, 60.8 years) underwent contrast-enhanced abdominal low-dose CT with 40% ASIR. All 53 patients had previously undergone contrast-enhanced routine-dose CT with FBP. With the scanning techniques masked, two radiologists independently graded images for sharpness, image noise, diagnostic acceptability, and artifacts. Quantitative measures of radiation dose and image noise were also obtained. All results were compared on the basis of body mass index (BMI).
Results:
The volume CT dose index (CTDI(vol)), dose-length product, and radiation dose for low-dose CT with ASIR were 17 mGy, 860 mGy, and 13 mSv, respectively, compared with 25 mGy, 1,193 mGy, and 18 mSv for routine-dose CT with FBP, representing an approximate overall dose reduction of 33%. Low-dose CT with ASIR had significantly reduced (p < 0.001) quantitative and qualitative assessment of image noise. Image sharpness, however, was significantly reduced for low-dose CT with ASIR (p < 0.001), although diagnostic acceptability and artifact scores were nearly identical to those for routine-dose CT with FBP. The average CTDI(vol) dose reduction was 66% for patients with a BMI of less than 20 and 23% for patients with a BMI of 25 or greater.
Conclusion:
Compared with routine-dose CT with FBP, abdominal low-dose CT with ASIR significantly reduces noise, thereby permitting diagnostic abdominal examinations with lower (by 23-66%) radiation doses. Despite reduced image sharpness in average and small patients, low-dose CT with ASIR had diagnostic acceptability comparable to that of routine-dose CT with FBP.
More Related Videos
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...