A comparison between internal and surface temperature measurement techniques during phacoemulsification cataract
B Innocenti1, S Diciotti, L Bocchi
1Department of Mechanics and Industrial Technology, University of Florence, Florence - Italy.
Purpose:
Corneal and scleral burns, one of the main complications that can occur during a cataract operation, are produced by overheating due to the use of the phacoemulsifier. The temperature of the anterior chamber of the eye can be measured both invasively using thermocouples and non-invasively, but only superficially, using a thermocamera.
Methods:
To compare the measures obtained from both techniques an in vitro experimental analysis was conducted on pigs' eyes. During a simulated phacoemulsification cataract operation both the surface temperature with a thermocamera and the temperature inside the anterior chamber with a thermocouple were recorded. For each procedure, the maximum temperature values measured by each technique were compared.
Results:
The results of this research show that the difference between the maximum values measured with the two techniques is on average 0.5 degrees C.
Conclusions:
It is possible to employ a thermocamera technique instead of a thermocouple technique to provide an indication of the temperature inside the anterior chamber.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...