Related Experiment Video
Updated: Jun 9, 2026

Natural Product Discovery with LC-MS/MS Diagnostic Fragmentation Filtering: Application for Microcystin Analysis
Published on: May 31, 2019
Analysis of microcystins by capillary zone electrophoresis coupling with electrospray ionization mass spectrometry
1Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, China.
Abstract:
In this paper, a rapid and effective method based on capillary zone electrophoresis (CZE) coupled with electrospray ionization mass spectrometry (ESI-MS) was established for the trace analysis of microcystin (MC) isomers in crude algae sample. The experimental conditions including the composition, acidity and concentration of buffer, separation voltage, injection time, and MS detection parameters were investigated in detail. A capillary separation system was as follows: a uncoated fused-silica capillary tube (50 microm i.d. x 90 cm), 40 mmol L(-1) ammonium acetate solution (pH 9.86) as running buffer, 25 kV as separation voltage, 20 kV x 3s water first and 20 kV x 20s for sample injection. Mass analysis was performed in ESI source, with sheath gas temperature 150 degrees C, sheath gas pressure 10 psi, and sheath gas flow 6 L min(-1). And sheath liquid was 7.5 mmol L(-1) acetic acid in 50% isopropanol-water (3 microg L min(-1)). Protonation and ammonium adduct molecular ions m/z 506.9 (MC-LR) and 532.0 (MC-YR) were used for the quantification of MCs. Under these conditions, two MCs were baseline separated within 9 min, the calibration curves were obtained in the range of 0.11-10.0 microg mL(-1) and 0.16-10.5 microg mL(-1) for MC-LR and MC-YR, respectively. Meanwhile, limits of detection were 0.05 and 0.08 microg mL(-1) for MC-LR and MC-YR, respectively. The recoveries for the two MCs were in the range of 95.8-108%. The developed approach had been successfully applied to the analysis of MCs in crude algae samples.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...