Lucilla Turco1, Stefano Provera, Ornella Curcuruto
1Analytical Chemistry, GlaxoSmithKline Medicines Research Centre, Via Fleming 4, 37135 Verona, Italy. lucilla.turco@aptuit.com
Abstract:
During late phase development of the selective NK1 receptor antagonist casopitant mesylate, a de-fluorinated impurity was discovered and quantified by an orthogonal analytical approach, using NMR and LC-MS. A dedicated (19)F NMR method was initially developed for first line identification and semi-quantification of the impurity. Subsequently, a more accurate quantification was achieved by means of a selective normal-phase LC-MS method, which was fully validated. The results obtained on the development batches of the drug substance were used by the project team to set up a suitable control strategy and ultimately to ensure patient safety and the progression of the project.