Double panel with skyhook active damping control units for control of sound radiation
Paolo Gardonio1, Neven Alujević
1DIEGM, Universita degli Studi di Udine Via delle Scienze, 208-33100 Udine, Italy. paolo.gardonio@uniud.it
Abstract:
This paper presents an experimental study on decentralized velocity feedback control on a double panel consisting of an external aluminum panel and a honeycomb trim panel. The decentralized feedback loops are formed by a 3x3 array of coil-magnet electrodynamic actuators that react off the trim panel and a lightweight stiff frame structure located in the air gap between the two panels. Microelectromechanical systems (MEMS) accelerometers are located on the opposite side of the trim panel in correspondence to the electrodynamic actuators. The grid structure is designed to provide an inertial reference to the actuators. In this way the velocity feedback control loops produce skyhook active damping on the double panel, which minimizes the vibrational response and sound radiation of the trim panel at low audio frequencies. Two configurations are considered where the grid structure is either weakly coupled or strongly coupled to the external panel. Both stability and control performance of the two configurations are analyzed experimentally. The study shows that the control configuration with the weakly coupled grid structure enables the implementation of larger stable feedback control gains, which lead to reductions of the sound radiated by the trim panel between 10 and 30 dB for the first seven resonance peaks.
Related Concept Videos
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Types of Damping
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Masonry Curtain Walls
Insulation Coordination
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.