Related Experiment Video
Updated: Jun 9, 2026

A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Investigation of optimal viewing size for detecting nodular ground-glass opacity on high-resolution computed
Michihiro Yamaguchi1, Yuichi Bessho, Tatsuro Inoue
1Department of Radiology, Osaka Prefectural Medical Center for Respiratory and Allergic Disease, Osaka Prefectural Hospital Organization, 3-7-1 Habikino, Habikino, Osaka, 583-8588, Japan. yamami@iris.eonet.ne.jp
Abstract:
We evaluated the effect of the displayed image sizes on observers' ability to detect nodular ground-glass opacity (n-GGO) on CT and investigated the optimal viewing size for soft-copy reading at CT screening for lung cancer. A total of 46 patients' high-resolution computed tomography (HRCT) images (22 patients with one GGO; 24 without GGO) were displayed on a monochromatic liquid crystal display monitor at a resolution of 1,200 × 1,600. HRCT was presented on the screen with cine-mode display. We compared two viewing sizes (original size, i.e., the image displayed with a zoom factor of 1 in which each pixel value in the image is displayed as one pixel on the display: 13 cm × 13 cm; fit size, i.e., by zooming the captured image until it occupies the entire screen: 30 cm × 30 cm) in terms of radiologists' performance for detecting n-GGO on HRCT and the viewing times required for soft-copy reading decisions. Observer performance was analyzed in terms of the receiver operating characteristic (ROC) curve. A statistically significant improvement was found with the original size in the average area-under-the-ROC curve values for the accuracy of diagnosis and the viewing times compared to the fit size (P < 0.05). The original size with cine-mode display leads to increased lung GGO detection at CT screening for lung cancer, and the reduced time spent performing the diagnosis offers cost savings.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT