Related Experiment Video
Updated: Jun 9, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Evaluation of chest and abdominal exposure dose appropriate for a digital image reader system incorporating a
Kyoko Saito1, Souichi Hiramoto, Tsutomu Gomi
1School of Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa, Japan. saitokyo@kitasato-u.ac.jp
Abstract:
We evaluated a newly developed digital image reader incorporating a columnar-crystal structured phosphor plate (CPP) to determine its effectiveness for chest and abdominal exposures by assessing contrast-detail (C-D) curves and image quality figure values obtained from a C-D phantom. With the help of five radiologic technologists with 5 years or more of experience in the interpretation of plain radiographs, we assessed chest and abdominal radiographic films that had undergone image processing. The exposure dose required for obtaining the same image quality under chest exposure conditions (110 kV) was 66% of that necessary for a conventionally used computed radiography system incorporating a powder phosphor plate, whereas the percentage under abdominal exposure conditions (85 kV) was 82%. The rate of dose reduction varied depending on the anatomic region radiographed, the exposure conditions applied, and the method of image processing employed. Because the CPP has a higher X-ray detection efficiency than the hitherto-used powder phosphor plate, its use has to potential to reduce the patients' radiation exposure dose.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Determination of Crystal Structures
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...