Background:
With anterior lumbar interbody fusion (ALIF) alone, the morbidity associated with a posterior approach can be avoided. In this study we evaluated the use of a PEEK cage with an integrated angle-stable locking plate (SynFix-LR™).
Material And Methods:
Thirty-two patients with osteochondrosis at L4/5 or L5/S1 were treated with the SynFix-LR™. Follow-up at 0, 3, 6, 9, 12, and 24 months included the Oswestry Disability Index (ODI), visual analog scale (VAS), and questions regarding satisfaction and use of pain medication. The fusion rate was assessed by X-ray and computed tomography (CT) examination.
Results:
A significant reduction of the ODI and VAS was achieved (p<0.05) with a high rate of patient satisfaction. After 2 years, 79% of the patients were able to dispense with long-term use of analgesics. We observed a fusion rate of 93% (X-ray) and 70% (CT) at final follow-up.
Conclusion:
The SynFix-LR™ device is a suitable option for the treatment of monosegmental osteochondrosis at L4/5 and L5/S1 with comparable or superior results in comparison to posterior or combined fusion techniques.