Related Experiment Video
Updated: Jun 9, 2026

Advanced 3D Liver Models for In vitro Genotoxicity Testing Following Long-Term Nanomaterial Exposure
Published on: June 5, 2020
Possibilities and limitations of modeling environmental exposure to engineered nanomaterials by probabilistic
Fadri Gottschalk1, Tobias Sonderer, Roland W Scholz
1Empa-Swiss Federal Laboratories for Materials Testing and Research, Technology and Society Laboratory, Lerchenfeldstr. 5, CH-9014 St. Gallen, Switzerland.
Abstract:
Information on environmental concentrations is needed to assess the risks that engineered nanomaterials (ENM) may pose to the environment. In this study, predicted environmental concentrations (PEC) were modeled for nano-TiO2, carbon nanotubes (CNT) and nano-Ag for Switzerland. Based on a life-cycle perspective, the model considered as input parameters the production volumes of the ENMs, the manufacturing and consumption quantities of products containing those materials, and the fate and pathways of ENMs in natural and technical environments. Faced with a distinct scarcity of data, we used a probabilistic material flow analysis model, treating all parameters as probability distributions. The modeling included Monte Carlo and Markov Chain Monte Carlo simulations as well as a sensitivity and uncertainty analysis. The PEC values of the ENMs in the different environmental compartments vary widely due to different ENM production volumes and different life cycles of the nanoproducts. The use of ENM in products with high water relevance leads to higher water and sediment concentrations for nano-TiO2 and nano-Ag, compared to CNTs, where smaller amounts of ENM reach the aquatic compartments. This study also presents a sensitivity analysis and a comprehensive discussion of the uncertainties of the simulation results and the limitations of the used approach. To estimate potential risks, the PEC values were compared to the predicted-no-effect concentrations (PNEC) derived from published data. The risk quotients (PEC/PNEC) for nano-TiO2 and nano-Ag were larger than one for treated wastewater and much smaller for all other environmental compartments (e.g., water, sediments, soils). We conclude that probabilistic modeling is very useful for predicting environmental concentrations of ENMs given the current lack of substantiated data.
More Related Videos
09:29An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
07:47Experimental Protocol to Investigate Particle Aerosolization of a Product Under Abrasion and Under Environmental Weathering
Published on: September 16, 2016
Related Concept Videos
Mechanistic Models: Compartment Models in Individual and Population Analysis
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Mechanistic Models: Overview of Compartment Models
Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions