Study Objective:
We measure the rate of emergency department (ED) specimen processing error reduction after implementation of an electronic physician order entry system paired with a bar-coded specimen labeling process.
Methods:
A cohort pre- and postintervention study was conducted in the ED during a 61-month period ending September 2008 in a large urban teaching hospital. Historically, laboratory order and requisition processing was done by hand. Interventions included implementing an ED-specific electronic documentation and information system, which included physician order entry with patient verification through bar-coded wristbands and bar-coded specimen labels. The main outcome measure was processing error rate, defined as unlabeled/mislabeled/wrong patient specimen or requisition. Pre- and postimplementation data were tabulated monthly and compared in aggregate by χ(2) test. The contribution of ED error to total institution specimen error was also calculated.
Results:
Of the 724,465 specimens collected preintervention, 3,007 (0.42%) were recorded as errors versus 379 errors (0.11%) of 334,039 specimens collected postintervention, which represents a 74% relative and 0.31% absolute decrease (95% confidence interval 0.28% to 0.32%). The proportion of institutional errors contributed by the ED was reduced from 20.4% to 11.4%, a 44% relative and 9.0% absolute reduction (95% confidence interval 7.7% to 10.3%). Subanalysis revealed that the majority of continued errors occur when the physician order entry/bar-code system could not be used (eg, blood bank or surgical pathology specimens).
Conclusion:
Combining an electronic physician order entry with bar-coded patient verification and electronic documentation and information system-generated specimen labels can significantly reduce ED specimen-related errors, with sizable influence on institutional specimen-related errors. Continued use of hand labeling and processing for special specimens appears inadvisable, though the cost-effectiveness of this intervention has not been established.
More Related Videos
08:58Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow
Published on: October 17, 2025
08:17A Semi-automated Approach to Preparing Antibody Cocktails for Immunophenotypic Analysis of Human Peripheral Blood
Published on: February 8, 2016
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Methods of Documentation V: CBE
In CBE, healthcare professionals establish predefined standards of practice that define what constitutes...