The effects of pre-ejection period on post-exercise systolic blood pressure estimation using the pulse arrival time
Mico Yee Man Wong1, Emma Pickwell-MacPherson, Yuan Ting Zhang
1The Joint Research Centre for Biomedical Engineering, Electronic Engineering Department, The Chinese University of Hong Kong, Shatin, Hong Kong.
Abstract:
Pulse arrival time (PAT) is comprised of the vascular transit time (TT) through the arterial system and the pre-ejection period (PEP) in the heart. It has been used to predict arterial blood pressure (BP) without using a cuff. The aim of this study was to investigate the effects of including the PEP on the accuracy of cuffless systolic BP (SBP) estimation using the PAT technique in post-exercise recovery. Experiments were conducted on 22 normotensive participants. PAT, TT and PEP were determined from simultaneous measurements of the electrocardiogram, photoplethysmogram and impedance cardiogram. Moderate exercise induced significant (p < 0.05) increases in SBP and heart rate and significant (p < 0.05) decreases in PEP and PAT. Diastolic blood pressure and TT only varied insignificantly (p > 0.05). SBP was moderately correlated with PEP (r = -0.61) and PAT (r = -0.81). PAT and PEP were moderately correlated (r = 0.67). When SBP was estimated using least-squares methods, the differences between the measured and predicted SBP using PEP, PAT and TT were 0.0 ± 6.6, 0.0 ± 4.9 and 0.0 ± 9.3 mmHg, respectively. The findings suggested that PAT gives the best SBP prediction and PEP has some potential to predict blood pressure. The inclusion of PEP in the PAT measurement is necessary to facilitate accurate cuffless blood pressure prediction after exercise.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: