Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Calculation of forward and backward arterial waves by analysis of two pressure waveforms
Gokul Swamy1, N Bari Olivier, Ramakrishna Mukkamala
1Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA. gokul.swamy@ge.com
Abstract:
We developed a technique to calculate forward and backward arterial waves from proximal and distal pressure waveforms. First, the relationship between the waveforms is represented with an arterial tube model. Then, the model parameters are estimated via least-squares fitting. Finally, the forward and backward waves are calculated using the parameter estimates. Thus, unlike most techniques, the arterial waves are determined without a more difficult flow measurement or an experimental perturbation. We applied the technique to central aortic and femoral artery pressure waveforms from anesthetized dogs during drug infusions, volume changes, and cardiac pacing. The calculated waves predicted an abdominal aortic pressure waveform measurement more accurately (2.4 mmHg error) than the analyzed waveforms (5.3 mmHg average error); reliably predicted relative changes in a femoral artery flow measurement (14.7% error); and changed as expected with selective vasoactive drugs. The ratio of the backward- to forward-wave magnitudes was 0.37 ± 0.05 during baseline. This index increased by ∼50% with phenylephrine and norepinephrine, decreased by ∼60% with dobutamine and nitroglycerin, and changed little otherwise. The time delay between the waves in the central aorta was 175 ± 14 ms during baseline. This delay varied by ±∼25% and was inversely related to mean pressure.
More Related Videos
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation