Field-controlled Luttinger liquid and possible crossover into spin liquid in strong-rail ladder systems

Lin-Jie Ding1, Kai-Lun Yao, Hua-Hua Fu

  • 1School of Physics and Wuhan High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan 430074, China.

Related Concept Videos

Two Components: Liquid–Liquid Systems01:27

Two Components: Liquid–Liquid Systems

A pressure-composition phase diagram explicitly describes the behavior of an ideal solution of two volatile liquids under varying pressures and compositions. A pressure-composition diagram has two main curves. The bubble point curve represents the plot of pressure versus liquid mole fraction. It indicates the pressure at which the first bubble of vapor forms from the liquid phase as the system pressure decreases.The dew point curve is the pressure versus vapor mole fraction. It indicates the...
Ladder Diagrams: Complexation Equilibria01:07

Ladder Diagrams: Complexation Equilibria

Ladder diagrams are useful for evaluating equilibria involving metal-ligand complexes. The vertical scale of the ladder diagram represents the concentration of unreacted or free ligand, pL. The horizontal lines on the scale depict the log of stepwise formation constants for metal-ligand complexes and indicate the dominant species in all the regions.
The formation constant, K1, for the formation of Cd(NH3)2+ complex from cadmium and ammonia is 3.55 × 102. Log K1 (i.e. pNH3) is 2.55, and...
Linear time-invariant Systems01:23

Linear time-invariant Systems

A system is linear if it displays the characteristics of homogeneity and additivity, together termed the superposition property. This principle is fundamental in all linear systems. Linear time-invariant (LTI) systems include systems with linear elements and constant parameters.
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be calculated...
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...