Related Experiment Video
Updated: Jun 8, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Preparation and evaluation of carbon coated alumina as a high surface area packing material for high performance
Changyub Paek1, Alon V McCormick, Peter W Carr
1Department of Chemistry, University of Minnesota, Smith and Kolthoff Halls, 207 Pleasant Street SE, Minneapolis, MN 55455, USA.
Abstract:
The retention of polar compounds, the separation of structural isomers and thermal stability make carbonaceous materials very attractive stationary phases for liquid chromatography (LC). Carbon clad zirconia (C/ZrO(2)), one of the most interesting, exhibits unparalleled chemical and thermal stability, but its characteristically low surface area (20-30 m(2)/g) limits broader application as a second dimension separation in two-dimensional liquid chromatography (2DLC) where high retentivity and therefore high stationary phase surface area are required. In this work, we used a high surface area commercial HPLC alumina (153 m(2)/g) as a support material to develop a carbon phase by chemical vapor deposition (CVD) at elevated temperature using hexane vapor as the carbon source. The loading of carbon was varied by changing the CVD time and temperature, and the carbon coated alumina (C/Al(2)O(3)) was characterized both physically and chromatographically. The resulting carbon phases behaved as a reversed phase similar to C/ZrO(2). At all carbon loadings, C/Al(2)O(3) closely matched the unique chromatographic selectivity of carbon phases, and as expected the retentivity was increased over C/ZrO(2). Excess carbon - the amount equivalent to 5 monolayers--was required to fully cover the oxide support in C/Al(2)O(3), but this was less excess than needed with C/ZrO(2). Plate counts were 60,000-76,000/m for 5 μm particles. Spectroscopic studies (XPS and FT-IR) were also conducted; they showed that the two materials were chemically very similar.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
