Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Two-Dimensional (2D) NMR: Overview01:12

Two-Dimensional (2D) NMR: Overview

The 1D NMR spectrum of large and complex molecules like natural products has complicated splitting patterns and overlapping signals, which can be easily interpreted using 2-dimensional (2D) NMR. Unlike 1D NMR, 2D NMR has two frequency axes that provide the coupling information between the nucleus A and nucleus B in a molecule. The process from which 2D spectra are obtained has four steps.
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse.
2D NMR: Overview of Homonuclear Correlation Techniques01:16

2D NMR: Overview of Homonuclear Correlation Techniques

Homonuclear correlation spectroscopy (COSY) is a powerful technique used in Nuclear Magnetic Resonance (NMR) spectroscopy to study the correlations between nuclei of the same type within a molecule. It provides information about scalar couplings between adjacent nuclei, which helps determine connectivity and structural information. There are several COSY variants, each with its unique strengths and experimental parameters.
COSY90 is the standard two-dimensional (2D) COSY experiment that...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)01:19

2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)01:06

2D NMR: Homonuclear Correlation Spectroscopy (COSY)

Homonuclear correlation spectroscopy, or COSY, is a 2-dimensional NMR technique that provides information about coupled protons. Typically, the geminal and vicinal coupling are observed. For example, consider the COSY spectrum of ethyl acetate, where its 1D proton NMR spectrum is plotted along the vertical and horizontal axes with their corresponding chemical shift scale. Three spots on the diagonal corresponding to the three peaks in the 1D proton spectrum are called diagonal peaks. The COSY...
2D NMR: Overview of Heteronuclear Correlation Techniques01:18

2D NMR: Overview of Heteronuclear Correlation Techniques

Heteronuclear correlation spectroscopy is an analytical technique that investigates the coupling between different types of nuclei, often a proton and an X-nucleus, such as carbon-13 or nitrogen-15. This method is commonly used in nuclear magnetic resonance (NMR) spectroscopy to gain insights into complex chemical compounds' structural and compositional aspects. A typical heteronuclear correlation spectrum displays X-nucleus chemical shifts on one axis and a proton spectrum on the other axis.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Radio emissions reveal Alfvénic activity and electron acceleration prior to substorm onset.

Nature communications·2025
Same author

In Flight Performance of the Far Ultraviolet Instrument (FUV) on ICON.

Space science reviews·2023
Same author

Intra-Annual Variation of Eddy Diffusion (k <sub></sub> ) in the MLT, From SABER and SCIAMACHY Atomic Oxygen Climatologies.

Journal of geophysical research. Atmospheres : JGR·2022
Same author

First ICON-FUV Nighttime NmF2 and hmF2 Comparison to Ground and Space-Based Measurements.

Journal of geophysical research. Space physics·2022
Same author

The Far Ultra-Violet imager on the ICON mission.

Space science reviews·2021
Same author

The Ionospheric Connection Explorer Mission: Mission Goals and Design.

Space science reviews·2021
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 8, 2026

A Multimodal Wide-Field Fourier-Transform Raman Microscope
06:48

A Multimodal Wide-Field Fourier-Transform Raman Microscope

Published on: December 30, 2025

Hadamard spectroscopy with a two-dimensional detecting array.

S B Mende, E S Claflin, R L Rairden

    Applied Optics
    |September 22, 2010
    PubMed
    Summary
    This summary is machine-generated.

    Replacing a spectrograph

    More Related Videos

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
    09:46

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

    Published on: April 28, 2022

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation
    10:52

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation

    Published on: February 4, 2017

    Related Experiment Videos

    Last Updated: Jun 8, 2026

    A Multimodal Wide-Field Fourier-Transform Raman Microscope
    06:48

    A Multimodal Wide-Field Fourier-Transform Raman Microscope

    Published on: December 30, 2025

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
    09:46

    Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

    Published on: April 28, 2022

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation
    10:52

    Direct Imaging of Laser-driven Ultrafast Molecular Rotation

    Published on: February 4, 2017

    Area of Science:

    • Spectroscopy
    • Optical instrumentation

    Background:

    • Conventional grating spectrographs use a single entrance slit.
    • This limits light throughput and signal-to-noise ratio (SNR).

    Purpose of the Study:

    • To investigate a novel technique for enhancing light throughput and SNR in grating spectrographs.
    • To evaluate the effectiveness of replacing the entrance slit with a mask.

    Main Methods:

    • Computer simulations were performed.
    • Laboratory tests were conducted to validate the technique.

    Main Results:

    • Replacing the entrance slit with a mask significantly increases light collection.
    • This leads to improved signal-to-noise ratio, especially for weak emission spectra and with detectors like CCDs that have background noise.
    • The spectral inversion process preserves SNR advantages.

    Conclusions:

    • Mask-based spectrograph design offers substantial signal-to-noise advantages.
    • This technique is valuable for observing faint astronomical and laboratory emission spectra.
    • It effectively mitigates detector background noise by increasing photon flux.