Related Experiment Video
Updated: Jun 8, 2026

Preparation of Authigenic Pyrite from Methane-bearing Sediments for In Situ Sulfur Isotope Analysis Using SIMS
Published on: August 31, 2017
In vacuo reduction of silver orthophosphate with graphite for high-precision oxygen isotope analysis
Andrzej Pelc1, Stanislaw Halas
1Mass Spectrometry Laboratory, Institute of Physics, Marie Curie-Sklodowska University, 20-031 Lublin, Poland. andrzej.pelc@poczta.umcs.lublin.pl
Abstract:
The reduction of silver phosphate with graphite under vacuum conditions was studied at final reaction temperatures varying from 430 to 915°C to determine: (i) the CO(2) extraction yield, and (ii) the oxygen isotopic composition of CO(2). The CO(2) yield and oxygen isotopic composition were determined on a calibrated dual inlet and triple collector isotope ratio mass spectrometer. We observed the following three stages of the reduction process. (1) At temperatures below 590°C only CO(2) is formed, while silver orthophosphate decays to pyrophosphate. (2) At higher temperatures, 590-830°C, predominantly CO is formed from silver pyrophosphate which decays to metaphosphate; this CO was always converted into CO(2) by the glow discharge method. (3) At temperatures above 830°C the noticeable sublimation of silver orthophosphate occurs. This observation was accompanied by the oxygen isotope analysis of the obtained CO(2). The measured δ(18)O value varied from -11.93‰ (at the lowest temperature) to -20.32‰ (at the highest temperature). The optimum reduction temperature range was found to be 780-830°C. In this temperature range the oxygen isotopic composition of CO(2) is nearly constant and the reaction efficiency is relatively high. The determined difference between the δ(18)O value of oxygen in silver phosphate and that in CO(2) extracted from this phosphate is +0.70‰.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
08:31Anaerobic Protein Purification and Kinetic Analysis via Oxygen Electrode for Studying DesB Dioxygenase Activity and Inhibition
Published on: October 3, 2018
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Atomic Absorption Spectroscopy: Atomization Methods
Washing, Drying, and Ignition of Precipitates
Volatilization
Sublimation