Related Experiment Video
Updated: Jun 8, 2026

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Evading metal adduct formation during desorption-ionization mass spectrometry
Chang-Ching Chan1, Mark S Bolgar, Scott A Miller
1Center for Mass Spectrometry, Department of Chemistry, Chemical Biology and Biomedical Engineering, Stevens Institute of Technology, Hoboken, NJ 07030, USA.
Abstract:
An investigation into the propensity of metal adduct formation in the recently developed Desorption Ionization by Charge Exchange (DICE) mass spectrometric technique has demonstrated that this method could be utilized to minimize spectral complications caused by metal adducts. For example, peaks for sodium and other metal adducts were not observed in the mass spectra acquired by the ambient-pressure DICE technique from samples deposited on a solid surface, even after the salt content of samples was deliberately increased. A mass spectrum recorded from a urine sample by this technique showed peaks only for the proton adducts of urea and creatinine. This technique employs a nebulized spray of charged toluene droplets for analyte desorption. Because of the non-polar nature of the spray reagent, it neither contains any appreciable amount of cations nor provides any favored 'pickup' of metal cations from the sample matrix. Consequently, peaks for metal adducts that are commonly observed with other desorption techniques are minimal or absent in the spectra recorded by the DICE method.
More Related Videos
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
06:21Imaging of Biological Tissues by Desorption Electrospray Ionization Mass Spectrometry
Published on: July 12, 2013
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Tandem Mass Spectrometry
Mass Spectrometry: Overview
Chemical Ionization (CI) Mass Spectrometry
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...