Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
L W J Bogert1, K H Wesseling, O Schraa
1Department of Internal Medicine, Academic Medical Centre, University of Amsterdam, Amsterdam, The Netherlands.
Abstract:
Pulse contour methods determine cardiac output semi-invasively using standard arterial access. This study assessed whether cardiac output can be determined non-invasively by replacing the intra-arterial pressure input with a non-invasive finger arterial pressure input in two methods, Nexfin CO-trek and Modelflow , in 25 awake patients after coronary artery bypass surgery. Pulmonary artery thermodilution cardiac output served as a reference. In the supine position, the mean (SD) differences between thermodilution cardiac output and Nexfin CO-trek were 0.22 (0.77) and 0.44 (0.81) l.min(-1) , for intra-arterial and non-invasive pressures, respectively. For Modelflow, these differences were 0.70 (1.08) and 1.80 (1.59) l.min(-1) , respectively. Similarly, in the sitting position, differences between thermodilution cardiac output and Nexfin CO-trek were 0.16 (0.78) and 0.34 (0.83), for intra-arterial and non-invasive arterial pressure, respectively. For Modelflow, these differences were 0.58 (1.11) and 1.52 (1.54) l.min(-1) , respectively. Thus, Nexfin CO-trek readings were not different from thermodilution cardiac output, for both invasive and non-invasive inputs. However, Modelflow readings differed greatly from thermodilution when using non-invasive arterial pressure input.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse
The pulse serves as a clinical indicator...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Measurement of Blood Pressure
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...