Arterial diameters on catheter and computed tomographic angiography
Sherise D Ferguson1, David S Rosen, Diana Bardo
1Section of Neurosurgery, Department of Surgery, University of Chicago Medical Center and Pritzker School of Medicine, Chicago, USA.
Background:
The diagnosis of cerebral vasospasm is hampered by lack of an accurate, noninvasive test. Computed tomographic angiography (CTA) may be useful but the correlation between arterial diameters determined from catheter digital subtraction angiography (DSA) and CTA over a range of artery sizes would need to be determined to show this. The purpose of this study was to determine the correlation between artery diameters measured on DSA and multidetector CTA.
Methods:
Two hundred forty artery diameters were measured in DSA and CTA from 46 patients who underwent both studies within 12 hours of each other. Axial cross section, maximum intensity projection, and volume-rendered images were measured and compared by linear correlation. Two independent readers measured CTA diameters to determine interobserver variability by linear correlation. Values also were categorized and compared by χ(2) and κ statistics. Analysis was repeated with unmeasurable arteries assigned a value of 0.
Results:
There were significant correlations between arterial diameters measured on DSA and those from CTA measured by any method (R(2) ranging from 0.45 to 0.76, P < .0001), although there was a tendency for the slope of this relationship to be less than 1, indicating underestimation of diameter of large and overestimation of diameter of small arteries with CTA. Computed tomographic angiography diameters also correlated significantly between the 2 reviewers with higher values often when unmeasureable arteries were assigned a value of 0 (κ = 0.23-0.55, P < .0001).
Conclusion:
Arterial diameters measured on multidetector CTA correlate well with those determined from DSA and should permit use of CTA for quantitative study of cerebral vasospasm and other conditions requiring accurate measurement of arterial diameters. The limitation of CTA remains the inability to measure some arteries due to artifact.
More Related Videos
10:09Drug Treatment by Central Venous Catheter in a Mouse Model of Angiotensin II Induced Abdominal Aortic Aneurysm and Monitoring by 3D Ultrasound
Published on: August 4, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...