The effects of BleedArrest, Celox, and TraumaDex on hemorrhage control in a porcine model
Related Experiment Video
Updated: Jun 8, 2026

Complete and Partial Aortic Occlusion for the Treatment of Hemorrhagic Shock in Swine
Published on: August 24, 2018
Brian Gegel1, James Burgert, Brian Cooley
1US Army Graduate Program in Anesthesia, Brooke Army Medical Center, Fort Sam, Houston, Texas 78234-6130, USA.
Background:
Hemorrhage is the second leading cause of death in civilian trauma and the leading cause of preventable death in military trauma. The purpose of this study was to examine the effectiveness of three hemostatic agents: BleedArrest, TraumaDex, and Celox.
Materials And Methods:
This was a prospective, experimental study using male Yorkshire swine. The pigs (n = 5 per group) were randomly assigned to one of the following: BleedArrest, TraumaDex, Celox, or control. To simulate a trauma injury, the investigators generated a complex groin injury with transection of the femoral artery and vein in all pigs. After 1 min of uncontrolled hemorrhage, one of the hemostatic agents was poured into the wound, followed by standard wound packing. The control group underwent the same procedures with the exception of the hemostatic agents. In all groups, 5 min of direct manual pressure was applied to the wound followed by a standard pressure dressing. After 30 min, dressings were removed, and the amount of bleeding was determined.
Results:
There were significant differences between the BleedArrest (mean = 21.2, SD ± 36.6 mL) TraumaDex (mean = 68, SD ± 103.5 mL) and Celox (mean = 18.l6, SD ± 41.6 mL) groups compared with Control group (mean = 230, SD ± 154 mL) (P < 0.05). However, there were no statistically significant difference between BleedArrest, TraumaDex, and Celox groups (P = 0.478).
Conclusions:
BleedArrest, Celox, and TraumaDex were statistically and clinically superior at controlling hemorrhage compared with the standard pressure dressing in the control group.