Background:
Sterrad sterilizers have been developed for the sterilization of thermolabile materials. The aim of the present study was to challenge the efficacy of this low-temperature hydrogen peroxide-based sterilization system with different carrier materials and wrappings under experimental "clean" and "dirty" conditions.
Methods:
We tested the sporocidal effect of the Sterrad 100NX sterilizer (Advanced Sterilization Products, Irvine, CA) on the carrier materials titanium, polyethylene, and polyurethane with single versus 3 wrappings of inoculated carriers. To simulate insufficient cleaning or crystalline residues, carriers were charged with spore inocula containing organic and inorganic burdens.
Results:
Our qualitative results show that irrespective of the number of wrappings in the "clean" condition, sterilization by the Sterrad 100NX was equally effective on all 3 carrier materials, reaching a log-10 reduction rate of ≥ 6 under standard half-cycle conditions. Any additional organic or inorganic challenge significantly impaired the sterilization outcome.
Conclusion:
Results of our current study emphasize the utmost importance of thorough and reliable cleaning of medical devices before being exposed to a subsequent hydrogen peroxide sterilization process. Any institution using this sterilization technology should have a well-established and validated cleaning process and enforce a rigorous quality assurance program for all steps of the presterilization processing of medical devices.
More Related Videos
09:30Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...