An Electrochemical Cholesteric Liquid Crystalline Device for Quick and Low-Voltage Color Modulation
Published on: February 27, 2019
Polychromatic target identification with a color liquid-crystal-TV-based joint-transform correlator
Applied Optics
|October 2, 2010
Summary
This study introduces a real-time polychromatic target-detection system using a computer-controlled liquid-crystal-TV joint-transform correlator (JTC). The adaptive JTC system effectively detects targets by analyzing both spatial and spectral information.
Area of Science:
- Optics and Photonics
- Image Processing
- Computer Vision
Background:
- Traditional target detection methods often struggle with complex spectral variations.
- Joint-transform correlators (JTCs) offer a framework for pattern recognition but can be limited in adaptability.
- Exploiting spectral information alongside spatial data is crucial for robust target identification.
Purpose of the Study:
- To present a novel real-time polychromatic target-detection technique.
- To leverage the spectral content of objects for enhanced detection capabilities.
- To develop an adaptive joint-transform correlator (JTC) system for flexible target recognition.
Main Methods:
- Implementation of a computer-addressable color liquid-crystal-TV based joint-transform correlator (JTC).
- Utilizing the polychromatic nature of the JTC to analyze spectral characteristics of targets.
- Developing adaptive control for manipulating the joint-transform power spectrum.
Main Results:
- Successful experimental demonstration of the proposed polychromatic JTC system.
- Validation of the technique's ability to detect targets based on both spatial and spectral features.
- Confirmation of the system's real-time processing capability.
Conclusions:
- The developed computer-addressable polychromatic JTC provides an effective real-time target-detection solution.
- Exploiting spectral information significantly enhances target detection accuracy and robustness.
- The adaptive nature of the JTC system allows for flexible and dynamic target recognition.
More Related Videos
Related Concept Videos
Color Vision
Color perception begins in the retina, the light-sensitive layer at the back of the eye. Two main theories explain how colors are seen: the trichromatic theory and the opponent-process theory. The trichromatic theory, proposed by Thomas Young in 1802 and extended by Hermann von Helmholtz in 1852, suggests that color vision is based on three types of cone receptors in the retina. These cones are sensitive to different but overlapping ranges of wavelengths corresponding to red, blue, and green.
High-Performance Liquid Chromatography: Types of Detectors
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
UV–Vis Spectroscopy of Conjugated Systems
Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent of conjugation in the...
One of the factors influencing λmax is the extent of conjugation in the...
IR Spectrum
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...