Related Experiment Video
Updated: Jun 8, 2026

FRET Microscopy for Real-time Monitoring of Signaling Events in Live Cells Using Unimolecular Biosensors
Published on: August 20, 2012
Signal/noise analysis of FRET-based sensors
Andrew Woehler1, Jakub Wlodarczyk, Erwin Neher
1DFG Research Center for the Molecular Physiology of the Brain, Göttingen, Germany.
Abstract:
Molecular sensors based on intramolecular Förster resonance energy transfer (FRET) have become versatile tools to monitor regulatory molecules in living tissue. However, their use is often compromised by low signal strength and excessive noise. We analyzed signal/noise (SNR) aspects of spectral FRET analysis methods, with the following conclusions: The most commonly used method (measurement of the emission ratio after a single short wavelength excitation) is optimal in terms of signal/noise, if only relative changes of this uncalibrated ratio are of interest. In the case that quantitative data on FRET efficiencies are required, these can be calculated from the emission ratio and some calibration parameters, but at reduced SNR. Lux-FRET, a recently described method for spectral analysis of FRET data, allows one to do so in three different ways, each based on a ratio of two out of three measured fluorescence signals (the donor and acceptor signal during a short-wavelength excitation and the acceptor signal during long wavelength excitation). Lux-FRET also allows for calculation of the total abundance of donor and acceptor fluorophores. The SNR for all these quantities is lower than that of the plain emission ratio due to unfavorable error propagation. However, if ligand concentration is calculated either from lux-FRET values or else, after its calibration, from the emission ratio, SNR for both analysis modes is very similar. Likewise, SNR values are similar, if the noise of these quantities is related to the expected dynamic range. We demonstrate these relationships based on data from an Epac-based cAMP sensor and discuss how the SNR changes with the FRET efficiency and the number of photons collected.
Related Concept Videos
Problem-Solving: Tuning of a Guitar String
The string's wave speed can be regulated by varying the linear density. Tension is the other property that determines the speed of...
Discrete Fourier Transform
Small-Signal Analysis of MOSFET Amplifiers
Signal and System
Signal Flow Graphs
In a signal-flow graph, branches denote the system's transfer functions, while nodes represent the signals. The direction of signal flow is indicated by arrows, with the corresponding...
Biasing of FET
In an N-channel JFET, the structure consists of N-type material forming the channel on a P-type substrate, with the gate...

