Related Experiment Video
Updated: Jun 8, 2026

Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Airway pressure release ventilation during adult donor care
David J Powner1, Russell Graham
1University of Texas Health Science Center at Houston, USA. david.j.powner@uth.tmc.edu
Abstract:
Airway pressure release ventilation is most commonly used during donor care to treat hypoxemia and to avoid high peak airway pressure. The traditional concept of cyclic inhalation/exhalation is replaced by a continuous positive airway inflation interspersed by brief episodes in which the positive pressure is reduced. The variables, Pressure-high, Pressure-low, Time-high, and Time-low, are manipulated to ensure adequate donor oxygenation and carbon dioxide removal. Organ procurement coordinators may find this method of mechanical ventilation in place when donor care is assumed or initiate it as a useful tool in providing donor support.
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation I: Indication and Settings