Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices01:28

Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices

Parenteral drug delivery systems play a crucial role in modern therapeutics by enabling the direct administration of drugs into the systemic circulation, bypassing the gastrointestinal tract. These systems are particularly valuable for poorly absorbed oral medications that are unstable in the digestive environment or require rapid onset or sustained therapeutic levels. Delivery is achieved through intravenous, intramuscular, or subcutaneous routes, each selected based on the drug's properties...
One-Compartment Model: IV Infusion01:09

One-Compartment Model: IV Infusion

Intravenous (IV) infusion is often utilized when continuous and controlled drug delivery is necessary, such as during surgery or in the treatment of chronic diseases. This method offers numerous advantages, including immediate drug action, precise control over dosage, and bypassing the first-pass metabolism.
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion01:15

Two-Compartment Open Model: IV Infusion

A two-compartment model is a vital tool in pharmacokinetics, providing an essential understanding of drug behavior, especially for those administered via zero-order intravenous infusion. This model outlines two compartments: the central compartment, where elimination occurs, and the peripheral compartment.
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Pharmaceutical Poisoning: Potential Scenarios01:26

Pharmaceutical Poisoning: Potential Scenarios

Pharmaceutical poisoning can occur through various channels, impacting an estimated 2 million hospitalized patients in the U.S. annually with serious adverse drug responses. These scenarios encompass both therapeutic uses, such as drug toxicity, where even standard dosages can lead to severe central nervous system depression, and non-therapeutic exposures, including accidental ingestion by children, and environmental and occupational exposures.Unintentional poisonings often involve exploratory...
Bioreactor Controls-I01:28

Bioreactor Controls-I

Maintaining optimal conditions within fermenters is essential for maximizing microbial productivity and ensuring process efficiency. This lesson focuses on key parameters—temperature, foam, pH, carbon dioxide, oxygen, and pressure—and their precise measurement and control strategies in fermentation systems.Temperature ControlTemperature regulation is critical due to the exothermic nature of many fermentation processes. In small laboratory fermenters, temperature is commonly monitored using...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions01:24

Drug Accumulation During Multiple Dosing: Intermittent IV Infusions

Intermittent intravenous (IV) infusion is a method of drug administration where medications are delivered over short infusion periods followed by intervals of no drug delivery. This approach helps to prevent sustained high drug concentrations in the bloodstream, reducing the risk of adverse effects associated with prolonged exposure. Unlike continuous infusion, steady-state concentrations may not be achieved during a single dosing cycle but can be reached through repeated...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Ensuring Medical Device Safety: The Role of Standards Organizations and Regulatory Bodies.

Journal of medical systems·2025
Same author

Machine Learning for Health: Algorithm Auditing & Quality Control.

Journal of medical systems·2021
Same author

Hey You, Get On the Cloud: Safe and Compliant Use of Cloud Computing with Medical Devices.

Biomedical instrumentation & technology·2021
Same author

Roundtable Discussion: In Medical Device Risk Management, Patients Take On Increased Importance.

Biomedical instrumentation & technology·2020
Same author

Setting Standards: Establishing Expectations for Artificial Intelligence Applications through Standards Development.

Biomedical instrumentation & technology·2020
Same author

Recent Advances in Systems and Network Medicine: Meeting Report from the First International Conference in Systems and Network Medicine.

Systems medicine (New Rochelle, N.Y.)·2020
Same journal

Improving Sterile Processing Operational Efficiency through Organizational Change.

Biomedical instrumentation & technology·2026
Same journal

Detecting Secondary Medication Infusion Errors via Spectrophotometry.

Biomedical instrumentation & technology·2026
Same journal

Inactivation of Endotoxin by Moist Heat, Electron Beam, and Gamma Irradiation.

Biomedical instrumentation & technology·2026
Same journal

Biological Indicators and Process Challenge Devices for Nitrogen Dioxide Sterilization.

Biomedical instrumentation & technology·2026
Same journal

Laparoscopic Instrument Defect Detection: A Prospective, Multisite Study.

Biomedical instrumentation & technology·2026
Same journal

Impact of Leadership Structures on Sterile Processing Performance and Patient Safety.

Biomedical instrumentation & technology·2026
See all related articles

Related Experiment Video

Updated: Jun 8, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
09:57

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit

Published on: July 13, 2019

Help us make infusion systems safer

Pat Baird1

  • 1pat_baird@baxter.com

Biomedical Instrumentation & Technology
|October 16, 2010
PubMed
Summary

No abstract available in PubMed .

More Related Videos

A Model of Chronic Nutrient Infusion in the Rat
08:18

A Model of Chronic Nutrient Infusion in the Rat

Published on: August 14, 2013

Construction and Implantation of a Microinfusion System for Sustained Delivery of Neuroactive Agents.
12:17

Construction and Implantation of a Microinfusion System for Sustained Delivery of Neuroactive Agents.

Published on: March 17, 2008

Related Experiment Videos

Last Updated: Jun 8, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
09:57

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit

Published on: July 13, 2019

A Model of Chronic Nutrient Infusion in the Rat
08:18

A Model of Chronic Nutrient Infusion in the Rat

Published on: August 14, 2013

Construction and Implantation of a Microinfusion System for Sustained Delivery of Neuroactive Agents.
12:17

Construction and Implantation of a Microinfusion System for Sustained Delivery of Neuroactive Agents.

Published on: March 17, 2008