Related Experiment Video
Updated: Jun 7, 2026

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Sensitized enantioselective laser-induced phosphorescence detection in chiral capillary electrophoresis
Ivonne Lammers1, Joost Buijs, Freek Ariese
1Department of Biomolecular Analysis and Spectroscopy, Laser Centre, Vrije Universiteit Amsterdam, De Boelelaan 1083, 1081 HV Amsterdam, The Netherlands.
Abstract:
The sensitivity of enantioselective cyclodextrin-induced room-temperature phosphorescence detection of camphorquinone (CQ) is enhanced using sensitization via a donor with a high extinction coefficient. The enantiomeric distinction is based on the different phosphorescence lifetimes of (+)-CQ and (-)-CQ after their complexation with α-cyclodextrin (α-CD). The collisional Dexter energy transfer from the selected donor 2,6-naphthalenedisulfonic acid (2,6-NS) to the acceptor CQ is still very efficient despite the inclusion of the acceptor into CD. For coupling to the chiral separation of (±)-CQ in cyclodextrin-based electrokinetic chromatography, the donor was added to the deoxygenated background electrolyte that consisted of 20 mM α-CD, 10 mM carboxymethyl-β-CD, and 25 mM borate buffer at pH 9.0. Time-resolved batch studies on sensitized phosphorescence show a significant enantioselectivity for (+)- and (-)-CQ in the presence of both α-CD and CM-β-CD although the lifetime difference is somewhat reduced with respect to direct excitation. The enantiomers were distinguished after their separation using an online time-resolved detection system. Excitation was performed at 266 nm with a pulsed, small-sized, quadrupled Nd:YAG laser. With 1 × 10(-5) M 2,6-NS, limits of detection of 4.1 × 10(-8) M and 5.2 × 10(-8) M were found for (+)-CQ and (-)-CQ, respectively. The online measured lifetimes were 238 ± 8 μs for (+)-CQ and 126 ± 10 μs for (-)-CQ. The method was used to determine the concentration of (±)-CQ leaching from a cured dental resin into water. The extracts contained 4.7 ± 0.1 × 10(-7) M of both (+)-CQ and (-)-CQ.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...