Cobalt hexaamine mediated electrocatalytic voltammetry of dimethyl sulfoxide reductase: driving force effects on

Kuan-I Chen1, Alastair G McEwan, Paul V Bernhardt

  • 1School of Chemistry and Molecular Biosciences, Centre for Metals in Biology, University of Queensland, Brisbane, QLD, 4072, Australia.

Related Concept Videos

Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
Redox Titration: Other Oxidizing and Reducing Agents01:26

Redox Titration: Other Oxidizing and Reducing Agents

Besides iodine, other oxidizing or reducing agents can serve as titrants in redox titrations. Common oxidizing titrants include KMnO4, cerium(IV), and K2Cr2O7. The choice of oxidizing titrants depends on factors like stability, cost, analyte strength, and reaction rate between the analyte and titrant. KMnO4 is a strong oxidizing titrant that reduces from Mn(VII) to Mn(II) in a highly acidic solution, simultaneously oxidizing the analyte to a higher oxidation state. In this case, KMnO4 acts as a...
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...